Smart Smoke Detector Wifi Smoke Sensor with CE, ROHS Certificate
Detail
Smoke detectors achieve fire prevention by monitoring the concentration of smoke. Ionic smoke sensors are used internally in smoke detectors. Ionic smoke sensors are technologically advanced, stable, and reliable sensors that are widely used in various fire alarm systems, with performance far superior to gas sensitive resistor type fire alarms.
It has a radioactive source of americium 241 inside the internal and external ionization chambers, and the positive and negative ions generated by ionization move towards the positive and negative electrodes under the action of an electric field. Under normal circumstances, the current and voltage of the inner and outer ionization chambers are stable. Once smoke escapes from the ionization chamber. If it interferes with the normal movement of charged particles, the current and voltage will change, disrupting the balance between the internal and external ionization chambers. Therefore, the wireless transmitter sends a wireless alarm signal to notify the remote receiving host and transmit the alarm information.
The smoke detector is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel. The conventional rate of rise of rise heat detector uses thermal component to detect the temperature changing in the environment. It can enable fire alam when the temperature difference achieved the setting rate of rise temperature value reach the setting fixed ualue. It has a stable and reliable working performance. Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption. The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
Parameter
Size |
120*40mm |
Battery Life |
>10 or 5 years |
Sound Pattern |
ISO8201 |
Directional Depending |
<1.4 |
Silence Time |
8-15 minutes |
Wattery |
10 years |
Power |
3V DC battery CR123 or CR2/3 |
Sound level |
>85db at 3 meters |
Smoke Sensitivity |
0.1-0.15 db/m |
Interconnection |
up to 48 pcs |
Operate Current |
<5uA(standby),<50mA(Alarm) |
Environment |
0~45°C,10~92%RH |