Manufacture 100-240Vac 50/60Hz security mode wireless gateway smart home alarm for convenience

Short Description:

The addressable fire alarm control panel is a dual wire analog bus system, it can replace the conventional fire alarm control system to save 50% or more cables.

Each detector, module, manual call point, horn, strobe ,hydrant has its own independent address, the fireman or the guard can find the exact fire alarm address instead of a wide area in conventional system.

The YNA-FAP9000 series addressable fire alarm control panel is an advanced, perfect and reliable system, it has been used in many countries.

2-wire intelligent fire alarm control panel is compatible with listed intelligent detector,intelligent module , intelligent call point, intelligent horn/strobe etc.


  • FOB Price: US $0.5 - 9,999 / Piece
  • Min.Order Quantity: 100 Piece/Pieces
  • Supply Ability: 10000 Piece/Pieces per Month
  • Product Detail

    Product Tags

    4 / 8 / 16 / 32 Zone Smoke Detection Control panel Conventional Fire Alarm Host System

    图片1

    Key attributes

    Other attributes

    Place of Origin

    Guangdong, China

    Brand Name

    Yongningan

    Model Number

    Xingda

    Nature

    Addressable

    Loop

    2~16 loops

    Capacity

    324 points per loop

    Circuit bus

    Non-polarity two buses

    Voltage

    24VDC/220VAC,50HZ~60HZ

    Certificate

    CE EN54

    Connectable

    Fire pump,Fire door,Smoke control and extraction fans

    Mini printer

    Yes

    Backup Battery

    Yes

    Real time clock

    Yes

     

    Product Overviews

    Ⅰ, Introduction:

    The addressable fire alarm control panel is a dual wire analog bus system, it can replace the conventional fire alarm control system to save 50% or more cables.

    Each detector, module, manual call point, horn, strobe ,hydrant has its own independent address, the fireman or the guard can find the exact fire alarm address instead of a wide area in conventional system.

    The YNA-FAP9000 series addressable fire alarm control panel is an advanced, perfect and reliable system, it has been used in many countries.

    2-wire intelligent fire alarm control panel is compatible with listed intelligent detector,intelligent module , intelligent call point, intelligent horn/strobe etc.

    Ⅱ,Character:

    1.    32-bit MCU

    2.    2-wire communication between detector/module

    3.    Each detector sensitivity adjustable

    4.    Field-programmable with PS/2 standard PC keypad and mouse

    5.    7.4′ LCD back-lit display

    6.    Windows menu and interface

    7.    Chinese or English interface and panel display

    8.    CF card duplicate or reset system setup file and history file to facilitate maintenance

    9.    Communicate with PC via USB

    10.Single point start/stop of module (Menu operation)

    11.Single point test of detector/module

    12.Zone, building or floor display

    13.CRT visually display the location of fire and trouble

    14.Eleven users each with a password and selectable access levels

    15.Field software upgrade

    16.20 YNA-FAP9000peer-to-peer, long-distance optical fiber transmission network via CAN communication transform module

    17.Flexible collocation by modularized combination

    Ⅲ,Standards that apply

    GB 4717-93 “General Technical Conditions for Fire Alarm Control Units”GB 16806-1997“General Technical Conditions of control for Fire Protection Equipment”

    CE certification

    IV ,Capacity

    1. Each I/O-board has two loops, with 324 alarm/control points of each loop (Max. control points-99), the capacity of each I/O-board :2×324=648(points).

    2. Each YNA-FAP9000 can connect maximum 3 I/O-boards, the capacity of each YNA-FAP9000:3×648=1944(points).

    3. Peer-to-peer with max. 20 YNA-FAP9000 , system capacity:20 ×1944=38880(points).

    4. Multi-line integrated control/monitoring capacity: Each YNA-FAP9000 can have maximum 25920 points.

    5. Busintegrated control capacity:Each YNA-FAP9000 can have maximum25920 points.

    6. Maximum simultaneous alarm of each host:

    Fire alarm:500,

    Trouble:500,

    Feedback:500

    V,Operating environment

    1. Temperature:-10℃~+55℃.

    2.Relative humidity:≤95%(40 ℃,non-condensing).

    3. AC power:220VAC,50Hz,3A.

    4.DC power:24VDC,7.0Ah

    图片3图片4

    图片5

    图片2

     

    Our Services

    1.fire alarm system full plan design:Yes

    2.fire alarm control panel technical support: Yes

    3.fire alarm control panel after sale service: Yes

    4.fire alarm control panel OEM/ODM: Yes

    5.fire alarm control panel warranty: 1 year

     

    FAQ

    1.MOQ: 1 pcs

    2.Delievry time :generally 5 to10 days .Mass product will be more.

    3.Payment terms :T/T L/C

     




    https://www.youtube.com/@XingDaElectricTechnology

    https://www.facebook.com/xingdaelectrictechnology

    https://www.instagram.com/xingdaelectrictechnology/


  • Previous:
  • Next: