2023 hot sales Volcano home alarms 10Y Battery Standalone smoke alarm detectors
4 / 8 / 16 / 32 Zone Smoke Detection Control panel Conventional Fire Alarm Host System
Key attributes
Other attributes
Place of Origin |
Guangdong, China |
Brand Name |
Yongningan |
Model Number |
Xingda |
Nature |
Addressable |
Loop |
2~16 loops |
Capacity |
324 points per loop |
Circuit bus |
Non-polarity two buses |
Voltage |
24VDC/220VAC,50HZ~60HZ |
Certificate |
CE EN54 |
Connectable |
Fire pump,Fire door,Smoke control and extraction fans |
Mini printer |
Yes |
Backup Battery |
Yes |
Real time clock |
Yes |
Product Overviews
Ⅰ, Introduction:
The addressable fire alarm control panel is a dual wire analog bus system, it can replace the conventional fire alarm control system to save 50% or more cables.
Each detector, module, manual call point, horn, strobe ,hydrant has its own independent address, the fireman or the guard can find the exact fire alarm address instead of a wide area in conventional system.
The YNA-FAP9000 series addressable fire alarm control panel is an advanced, perfect and reliable system, it has been used in many countries.
2-wire intelligent fire alarm control panel is compatible with listed intelligent detector,intelligent module , intelligent call point, intelligent horn/strobe etc.
Ⅱ,Character:
1. 32-bit MCU
2. 2-wire communication between detector/module
3. Each detector sensitivity adjustable
4. Field-programmable with PS/2 standard PC keypad and mouse
5. 7.4′ LCD back-lit display
6. Windows menu and interface
7. Chinese or English interface and panel display
8. CF card duplicate or reset system setup file and history file to facilitate maintenance
9. Communicate with PC via USB
10.Single point start/stop of module (Menu operation)
11.Single point test of detector/module
12.Zone, building or floor display
13.CRT visually display the location of fire and trouble
14.Eleven users each with a password and selectable access levels
15.Field software upgrade
16.20 YNA-FAP9000peer-to-peer, long-distance optical fiber transmission network via CAN communication transform module
17.Flexible collocation by modularized combination
Ⅲ,Standards that apply
GB 4717-93 “General Technical Conditions for Fire Alarm Control Units”GB 16806-1997“General Technical Conditions of control for Fire Protection Equipment”
CE certification
IV ,Capacity
1. Each I/O-board has two loops, with 324 alarm/control points of each loop (Max. control points-99), the capacity of each I/O-board :2×324=648(points).
2. Each YNA-FAP9000 can connect maximum 3 I/O-boards, the capacity of each YNA-FAP9000:3×648=1944(points).
3. Peer-to-peer with max. 20 YNA-FAP9000 , system capacity:20 ×1944=38880(points).
4. Multi-line integrated control/monitoring capacity: Each YNA-FAP9000 can have maximum 25920 points.
5. Busintegrated control capacity:Each YNA-FAP9000 can have maximum25920 points.
6. Maximum simultaneous alarm of each host:
Fire alarm:500,
Trouble:500,
Feedback:500
V,Operating environment
1. Temperature:-10℃~+55℃.
2.Relative humidity:≤95%(40 ℃,non-condensing).
3. AC power:220VAC,50Hz,3A.
4.DC power:24VDC,7.0Ah
Our Services
1.fire alarm system full plan design:Yes
2.fire alarm control panel technical support: Yes
3.fire alarm control panel after sale service: Yes
4.fire alarm control panel OEM/ODM: Yes
5.fire alarm control panel warranty: 1 year
FAQ
1.MOQ: 1 pcs
2.Delievry time :generally 5 to10 days .Mass product will be more.
3.Payment terms :T/T L/C